Product Details:
Control Type | PID On/ Off |
No of digits | 4+4 |
Mounting Type | DIN Track Mounting |
Display Size | 48*48 mm |
Output type | SSR |
Sensor Input | Thermocouple, RTD |
Protection | IP50 (Front panel) |
Power supply | 100-240VAC 50/60Hz |
Power consumption | Max. 8VA |
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF, P, PI, PD, PID |
Input specification | Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω Analog: 0-100mV, 0-5V, 1-5V, 0-10V 0-20mA, 4-20mA |
Sampling cycle | 50ms |
Control output 1 | Current(DC0/4-20mA) or SSR drive(11VDC ) [ON/OFF] |
Control output 2 | Relay(250VAC~ 3A) |
Option input | CT, Digital(DI-1) |
Option output | Alarm 1/2, RS485 comm. |
Power supply | 100-240VAC~ 50/60Hz |
Protection structure | IP65(front panel) |
Display accuracy_RTD | •At room temperature(23±5):(PV ±0.3% or ±1, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2, select the higher one) ±1-digit |
Display accuracy_Thermocouple | •At room temperature(23±5):(PV ±0.3% or ±1, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2, select the higher one) ±1-digit |
Display accuracy_Analog | •At room temperature(23±5): ±0.3% F.S. ±1-digit •Out of range of room temperature: ±0.5% F.S. ±1-digit |
Display accuracy_CT input | ±5% F.S. ±1-digit |
Hysteresis(adjustable sensitivity) | RTD/Thermocouples: 1 to 100/(0.1 to 100.0/) variable Analog: 1 to 100-digit |
Proportional band | 0.1 to 999.9/(0.1 to 999.9%) |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | Relay output, SSR drive output: 0.1 to 120.0 sec Current output or SSR drive output selectable: 1.0 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50, storage: -20 to 60 |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 2kV) |
Weight | Approx. 150g(approx. 105g) |
Product Details:
Environment_Ambient humidity | 35 to 85%RH |
Sampling Duration | 50ms |
Power supply | 100-240VAC 50/60Hz |
Power consumption | Max. 8VA |
Allowable voltage range | 90 to 110% of rated voltage |
Protection | IP65 (Front panel) |
Ambient temperature | -10 to 50 Celsius |
Display method | 4-digit 7-segment LED |
---|---|
Control method | ON/OFF control, P, PI, PD, PID control |
Input specification | Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II RTD: DPt100?, DPt50℃, JPt100?, Cu100?, Cu50℃, Nikel 120? Analog: 0-100mV, 0-5V, 1-5V, 0-10V 0-20mA, 4-20mA |
Sampling cycle | 50ms |
Control output 1 | Current(DC0/4-20mA) or SSR drive(11VDC) [ON/OFF] |
Option input | CT, Digital(DI-1) |
Option output | Alarm 1 |
Power supply | 100-240VAC~ 50/60Hz |
Protection structure | IP65(front panel) |
Display accuracy_RTD | •At room temperature(23?±5?):(PV ±0.3% or ±1?, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2?, select the higher one) ±1-digit |
Display accuracy_Thermocouple | •At room temperature(23?±5?):(PV ±0.3% or ±1?, select the higher one) ±1-digit •Out of room temperature:(PV ±0.5% or ±2?, select the higher one) ±1-digit |
Display accuracy_Analog | •At room temperature(23?±5?): ±0.3% F.S. ±1-digit •Out of range of room temperature: ±0.5?% F.S. ±1-digit |
Display accuracy_CT input | ±5% F.S. ±1-digit |
Hysteresis(adjustable sensitivity) | RTD/Thermocouples: 1 to 100℃/℉(0.1 to 100.0℃/℉) variable Analog: 1 to 100-digit |
Proportional band | 0.1 to 999.9?/?(0.1 to 999.9%) |
Integral time | 0 to 9999 sec |
Derivative time | 0 to 9999 sec |
Control period | Relay output, SSR drive output: 0.1 to 120.0 sec Current output or SSR drive output selectable: 1.0 to 120.0 sec |
Manual reset | 0.0 to 100.0% |
Environment_Ambient temperature | -10 to 50?, storage: -20 to 60℃ |
Environment_Ambient humidity | 35 to 85% RH, storage: 35 to 85% RH |
Insulation type | Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 2kV) |
Weight | Approx. 150g(approx. 105g) |